Home >>
Products >>
Laboratory Products >>
Tempered Water System™
SciLog Tempered Water System™
Do you need sterile, hot media delivered quickly and in high precision aliquots? Then you need the SciLog Tempered Water System.
The SciLog Tempered Water System is a walk-up food microbial sample prep station that quickly and easily delivers hot water in high precision aliquots to your pre-packaged media packet (such as DuPont StatMedia).
Simplify your food microbial sample prep with SciLog s Tempered Water System (TWS):
- No autoclaving of your water and/or media needed.
SciLog s TWS filter sterilizes the hot water as you need it.
- No storage of large media filled containers needed.
Dispense the water/media as you need it. Eliminates storage issues and investment of large quantities of containers.
- No media storage in incubators.
Because TWS filter sterilizes the water/media as you need it, No need to worry about storing and having enough media available when you need it. It is available on-demand with the SciLog Tempered Water System.
- Speed up the microbial testing process of cold samples.
Simply drop your cold samples (e.g.: cold meat samples) into the hot, temperature controlled media.
The SciLog Tempered Water System™ delivers its ease of use and accelerated media preparation through the combined use of:
- An on-board, in-line water heater that maintains water temperature at a predetermined level during recirculation (between 32° and 48° Celcius),
- An in-line sterilizing filter,
- An in-line disposable pressure sensor (the SciLog SciPres™) that monitors the status of the filter,
- An on-board automated alarm system,
- A SciLog LabTec™ high precision, programmable dispensing unit,
- A SciLog ACCU™ recirculation pump,
- DuPont™ StatMedia™ water soluble packets for microbial enrichment media,
- An optional scale (not pictured) is available for dispensing by weight
Dispensing accuracy and precision is assured with a simple, single key re-calibration feature. For ease of use, up to ten user-defined dispensing volumes can be stored in the LabTec . For inventory control purposes all dispensing activity can be tracked on the easy-to-read display or documented and archived in your PC.
LabTec Automated Dispensing System The LabTec Peristaltic Dispensing System automates the dispensing and diluting of samples. The LabTec has three different dispensing capabilities:
- Volumetric Dispensing: Programmable batch-volume dispensing, e.g. the LabTec dispenses 10.00 ml in three seconds with a typical precision of better than 1%. Easy to enter and change aliquot sizes.
- Weight Dispensing: The LabTec can be interfaced with an electronic balance for dispensing solutions by weight rather than by volume. Dispensing liquids by weight eliminates the need for pump calibrations while, at the same time, providing a level of accuracy and precision.
- Weight Ratio Dispensing: The LabTec can be connected to an electronic scale platform to automatically weigh and dilute samples. Example: for a sample weighing 11.0 grams, the LabTec will automatically dispense 99.0 grams of diluent if the user defined weight ratio is set at 9.00. The LabTec will take 15 seconds to weigh the sample and to dispense the diluent; the typical dispensing precision is better than 0.5%.
LabTec Sample Preparation For Bacteriological Analysis Automated weighing and diluting of food samples can be readily implemented with SciLog's low cost LabTec dispenser. Only an approximate food sample size is needed. The SciLog LabTec dispenser calculates and rapidly dispenses the required diluent. LabTec dispenser increases the speed and increases the precision of the entire sample prep process by automating the weighing as well as the dilution process.
| Dimension: |
Width: 5.75 in (14.6cm); Height: 8.5 in (212.6); Depth: 11in (27.9). |
| Weight: |
14 lbs (6.4kg) |
| Enclosure: |
16 Ga, aluminum baked epoxy blue |
| LabTec Models: |
Optimal range for precision and speed of dispensing:
1. LabTec CP-120: 0.2 ml to 50 ml aliquots of low viscosity, aqueous liquids. Typical precision 0.5% by vol. Tandem 1081 peristaltic pump head with variable speed max. 160 RPM motor
2. LabTec CP-200: 10 ml to 2 liter aliquots of low or high viscosity liquids. Typical precision 0.5% by vol. Use with any thick, viscous liquids. Tandem 1082 peristaltic pump head with variable speed max. 600 RPM motor.
3.LabTec MP-320: 4 ml to 3 liter aliquots of organic solvents, low viscosity. Typical precision 0.5% by vol. liquids. Magnetic gear head, 316SS chamber with Teflon gears with variable speed max. 3400 RPM motor
|
| Pressure Range: |
Maximum pressure output at tandem peristaltic pump head is 45 psi. Has single point recalibration feature. |
| Pressure Displayed: |
Pressure displayed with a resolution of 0.1 psi; choice of bar, psi, kpa |
| Pressure Sensors Options: |
Use with sterilizing filters to monitor filter back pressure and to alarm when need to change filter due to plugging up of filter. |
| Power: |
115/220-240 VAC, 60/50Hz, 75 Watts; double fused: T1AL 250V (CE: IR35A 250VAC) |
| Re-Cal Feature: |
Factory installed calibration curve for all tubing sizes. Front panel Re-cal key for single-point pump recalibration. |
| LabTec™ Balance Options: |
1. Balance with capacity of 2,000 grams x 0.01 g and 8,100 g x 0.1 resolution are most popular. 2. Larger balance capacities up to 30 Kg x 0.1 g resolution available. |
| LabTec™ Software: |
1. Dispenses by volume, rapidly and with high precision 2. Dispenses by weight, used with balance for rapid high precision filling by weight 3. Weight ratio, automates weighing and diluting process and sample prep process 4. Monitors back pressure of in-line sterilizing filters 5. Alarms when back pressure of in-line sterilizing filter is plugged up and can no longer be used.
|
| Documentation Software for PC: |
1. SciDoc interface software with custom macros for Excel for data compilation. Sent to you ready to use. 2. Complete process analysis with graphing of data. 3. Real-time verification and documentation of process parameters. |
| Use Range: |
4 to 40 C, 100% Humidity |
| Motor: |
Choice between three (3) motors: 160, 600, 3600 RPM at 30VDC, 3.8 Amps, Variable Pump Speed, optically encoded servo-controlled motors. |
| I/O Ports: |
1. First serial port labeled Balance , Male DB9 connector for hook-up of electronic scale. 2. Second Serial Port labeled "Printer", Female DB9; also used to interface to PC for data storage in an Excel file in your PC. 3. External I/O port, Female DB37 connector; Used for remote On/Off control of FilterTec via footswitch. 4. Optional pressure sensor interface available |
| Data Entry: |
Membrane keyboard with auditory feedback. |
| LabTec Settings: |
- Save 10 Optimized Dispensing by Volume settings for rapid, high precision filling, from ml to liter aliquots; Typical precision of 0.5% by volume. - Save 10 Optimized Dispensing by Weight settings for rapid, high precision filling by weight from grams to kilograms aliquots; Typical precision of 0.3% by weight. - Save 10 Optimized Weight Ratio settings to automate the weighing and diluting process in sample preparation; Typical precision of 0.3% or better. - Document each dispense or dilution for GLP or for inventory control; print out or data sent to spreadsheet in PC. (SciDoc feature) |
© Copyright SciLog, Inc.
| Dimension: |
5.75 Width x 6.25 Height x 11 Depth |
| Weight: |
11 lbs. |
| Enclosure: |
16 Ga, aluminum baked epoxy blue |
| ACCU Motor: |
Variable speed, 8 RPM, 160 RPM, 450 RPM, 600RPM and 3400 RPM motors at 28 VDC, 3.8 Amps; optically encoded, servo - controlled.
|
| Power: |
110 / 220 VAC , 60 / 50 Hz, 75 Watts; double fused |
| Encoder: |
120 lines per motor revolution. |
| Use Range: |
4 to 40 C, 100% Humidity |
| Motor: |
Choice of five (5) motors: 8, 160, 600, 450 and 3400 RPM at 30VDC, 3.8 Amperes, Variable Pump Speed, optically encoded servo-controlled motors. |
| I/O Ports: DB 15 (Back Panel) |
1. RS-232 Serial port, DB15 connector, pin 2 (Transmit), pin 3 (Receive) & pin 5 (Ground)
2. 4-20 mA input signal, DB 15 connector, pin 6 (Ground) & pin 13, with selection switch (back panel) at 4-20 mA
3. 0-5VDC input signal, DB 15 connector, pin 6 (Ground) & pin 13, with selection switch (back panel) at 0-5VDC
4. Pump Speed output signal, DB 15 connector, pulsed output between pins 7 (Ground) & pin 9, pulse rate is proportional to pump speed, ~5940 pulses/sec at 99% pump speed, ~3000 pulses/sec at 50% pump speed.
5. Remote Start/Stop ( Remote ), closed contact closure (RUN), open contact closure (STOP) between pin 8 (Ground) & pin 15 of the DB 15 connector. This function is active when REMOTE has been selected from the front panel.
6. Remote CW/CCW Motor Direction ( Remote ), closed contact closure (CCW), open contact closure (CW) between pin 7 (Ground) & pin 14. This function is active when the REMOTE mode has been selected from the front panel.
7. Remote Start/Stop ( Local ), closed contact closure (RUN), open contact closure (STOP) between pin 8 (Ground) & pin 15 of the DB 15 connector. This function is active when the LOCAL mode has been selected from the front panel and the external contact closures (CC across pin 8 & 15) has been exercised, i.e. opening and closing the connected contact closures (CC). The front panel RUN/STOP key will be disabled at that point, however, the pump speed selection and the CW/CCW keys are still functional. The front panel RUN/STOP key function can be re-established by twice pressing the LOCAL/REMOTE key. NOTE: This operational mode should only be used when the ACCU pump is to be controlled (Stop/Start) by a SciLog Smart Pump, i.e. UltraTec or ChemTec.
8. Foot Switch Start/Stop ( Local ), foot switch acts as an external contact closure, pump runs at the selected pump speed as long as the foot switch contact is closed, i.e. as long as you step on the foot switch. The pump stops when the foot switch contact is open.
|
| Data Entry: |
Membrane keyboard, 2 LED's with auditory feedback. |
© Copyright SciLog, Inc.
| Material, Fluid Contact: |
Natural PP meet USP Class VI and FDA 21 CFR 177.1520. All wetted materials are made of animal-free compounds. Compatible with most sanitizing agents such as NaOH for flow cell sanitization. |
| Sensor Type: |
Medical Grade, Piezoresistive Sensing Element with on-chip temperature compensation |
| Sensor Isolation: |
Insoluble silicone dielectric gel isolates sensing element from process solution. The gel is a non-toxic, non-allergenic elastomer system that meets all USP XX Biological Class V requirements. |
| Pressure Range: |
0 - 60 psi: Luer, 0.375" Barb and 0.500" Barb Sensors.
0 - 90 psi: for 0.750" TC and 1.00" TC Ladish Sensors |
Pressure Accuracy: |
+/- 0.30 psi at 60 psi |
Pressure Resolution: |
0.01 psi Temperature Range: 0-60° C |
| Sensor Microchip: |
EPROM, Stored Sensor ID and Calibration Factor |
Sensor Connector Cables: |
Lockable & Waterproof |
| Sanitization: |
Can be sanitizied with NaOH, NaOCl, Formaldehyde, etc |
Available Connector Types: |
Luer, 3/8" Barb, 1/2" Barb, 3/4" TC, and 1.0" TC |
Compatible Tubing Sizes:
|
Luer: ID 0.03" to 0.31"
3/8" Barb: ID 0.31" to 0.38"
1/2" Barb: ID 0.50"
3/4" TC: Tubing with 3/4" TC
1.0" TC: Tubing with 1" TC Ladish
|
Maximum Flow Rate: |
Luer: 2 liters/min
3/8" Barb: 8 liters/min
1/2" Barb: 17 liters/min
3/4" TC: 30.5 liters/min
1.0" TC: 60 liters/min
|
Maximum Pressure:
|
Luer: 60 psi
3/8" Barb: 60 psi
1/2" Barb: 60 psi
3/4" TC: 100 psi
1.0" TC: 100 psi
|
| Part Numbers:
|
Luer: 080-693
3/8" Barb: 080-691
1/2" Barb: 080-692
3/4" TC: 080-698
1.0" TC: 080-697
|
*Patents Pending
© Copyright SciLog, Inc.
|