Home >>
Products >> Laboratory Products
SciLog Laboratory Products
PureTec™ Systems - Protein Purification & Diafiltration
| Dimensions |
Width: 5.75 in (14.6cm); Height: 8.5 in (21.2cm); Depth: 11in (27.9cm) |
| Weight: |
14 lbs (6.4kg) |
| Enclosure: |
16 Ga, aluminum baked epoxy blue |
| PureTec Models: |
PureTec CP-8 PureTec CP-120 PureTec CP-200
Tandem 1081 peristaltic pump head with variable speed max. 8 RPM motor, Flow Range (depending on tubing size): 0.03 to 24.3 ml/min. Tandem 1081 peristaltic pump head with variable speed max. 160 RPM motor, Flow Range (depending on tubing size): 0.5 to 554 ml/min. Tandem 1081 & Tandem 1082 peristaltic pump heads mounted piggyback with variable speed max. 600 RPM motor, Flow Range (depending on tubing size): 2 to 2,258 ml/min. Tandem 1081 uses Masterflex peristaltic pump tubing (thin-walled) sizes: #13, 14, 16, 25, 17 & 18. Tandem 1082 uses Masterflex peristaltic pump tubing (thick-walled) sizes: #15, 24 & 35. |
| Pressure Range: |
Tandem Head Pump Maximum pressure output at tandem peristaltic pump head is 45 psi. Has single point recalibration feature. |
| Pressure Displayed: |
Pressure displayed with a resolution of 0.1 psi; choice of bar, psi, kpa. |
| Pressure Sensors: |
Accommodates up to three (3) disposable pressure sensors. The calibrated pressure range is 0-60 psi. Any point within this range can be re-calibrated using an external pressure reference source. |
| Power: |
115/220-240 VAC, 60/50Hz, 75 Watts; double fused: T1AL 250V (CE: IR35A 250VAC) |
| Encoder: |
100 lines per motor revolution for 600 RPM motor. 120 lines per motor revolution for 8 and 160 RPM motors. |
| PureTec Balance Options:
|
-Balance with capacity of 2,000 grams x 0.01 g resolution included with PureTec CP-8.
-Balance with capacity of 8,100 grams x 0.1 g resolution included with all other PureTec models.
|
| PureTec Software:
|
Main menu with five operational modes including:
-Rate Mode: Constant Rate Filtration with five user-definable alarms.
-Pressure Mode: Constant Pressure Filtration with five user-definable alarms.
-Choice of Inlet Pressure or TransMembrane Pressure for Control and Alarm.
|
| Documentation Software for PC:
|
-SciDoc interface software with custom macros for Excel for data compilation. Sent to you ready to use.
-Complete process analysis with graphing of data.
-Real-time verification and documentation of process parameters.
|
| Use Range:
|
4 to 40 C, 100% Humidity.
|
| Motor:
|
Choice of three (3) motors: 8, 160 and 600 RPM at 24 VDC, 3.8 Amperes, Variable Pump Speed, optically encoded servo-controlled motors.
|
| I/O Ports:
|
1. First serial port labeled Balance , Male DB9 connector for hook-up of electronic scale.
2. Second Serial Port labeled Printer , Female DB9; also used to interface to PC for data storage in an Excel file in your PC.
3. External I/O port, Female DB37 connector; Used for remote On/Off control of PureTec via footswitch.
4. Pressure Sensor Box: Phone plugs for three(3) pressure sensors.
|
| Data Entry:
|
Membrane keyboard with auditory feedback.
|
| Pall® TFF Device Filter Area Cross Flow Rate Tubing Pump Head / Motor PureTec Model
|
| Minimate 0.05 30 - 50 #16 Tandem1081 / 160RPM PureTec CP-120
|
| LV-Centramate 0.1 - 0.2 70 - 140 #16, #25 Tandem1081 / 160RPM PureTec CP-120
|
| Centramate 1.0 - 3.0 700 - 2100 #24, #35 Tandem1082 / 600RPM PureTec CP-200
|
| Notes: The PureTec™ is also compatible with equivalent TFF devices made by Millipore and Sartorius. For nano-filters used in virus filtration, the PureTec CP-8 is recommended, which comes with an 8 RPM motor and a 1081 peristaltic pump head and generates pump rate from 0.03 to 24.3 ml/min.
|
© Copyright SciLog, Inc.
Protein purification system. Automates crossflow filtration, protein concentration, diafiltration, and protein washing. Controls & monitors TMP (transmembrane pressure). Interfaces with three Disposable Pressure Sensors and a Disposable Temperature Sensor. Ideal for lab scale TFF (tangential flow filtration). 500 ml reserviour standard, 50 ml, 1000ml and a Filter Manifold are available. SciDoc Documentation package for MS Excel is available for documenting the process.
Tempered Water System™ - Rapid & Easy Food Microbial Sample Prep
|
Sample Performance Validation #1
|
Aliquote Size:
Average:
Standard Deviation:
RSD (%):
Time:
|
225 ml
224.7 ml
0.952
0.141
4 Seconds
|
|
Sample Performance Validation #2
|
Aliquote Size:
Average:
Standard Deviation:
RSD (%):
Time:
|
1500 ml
1503.01 ml
0.923
0.061
28 Seconds
|
|
Sample Performance Validation #3
|
Aliquote Size:
Average:
Standard Deviation:
RSD (%):
Time:
|
3375 ml
3377.68
1.422
0.042
59 Seconds
|
© Copyright SciLog, Inc.
The SciLog Tempered Water System™ (TWS) is a walk-up food microbial sample preparation station that quickly and easily delivers hot water in high precision aliquots to your pre-packaged media packet (such as DuPont™ StatMedia™). No autoclaving of your water and/or media needed. No storage of large media filled containers needed. No media storage in incubators. Speed up the microbial testing process of cold samples.
FilterTec™ Systems - Dead end Filtration (Direct flow)
| Dimension: |
Width: 5.75 in (14.6cm); Height: 8.5 in (212.6); Depth: 11in (27.9). |
| Weight: |
14 lbs (6.4kg) |
| Enclosure: |
16 Ga, aluminum baked epoxy blue |
| Pump Head/ Motor Options: |
1. Tandem 1081 peristaltic pump head with 8 RPM motor. Flow range (depending on tubing size): 0.03 to 24 ml/min. 2. Tandem 1081 peristaltic pump head with 160 RPM motor. Flow range (depending on tubing size): 0.5 to 554 ml/min. 3. Tandem 1082 peristaltic pump head with 600 RPM motor. Flow range (depending on tubing size): 0.59 to 2,258 ml/min. 4. Tandem 1081 peristaltic pump head with 600 RPM motor. Flow range (depending on tubing size): 2 to 1,500 ml/min. |
| Pressure Range: |
Tandem Head Pump: Maximum pressure output at tandem peristaltic pump head is 45 psi. Has single point recalibration feature. |
| Pressure Displayed: |
Pressure displayed with a resolution of 0.1 psi; choice of bar, psi, kpa |
| Pressure Sensors: |
Accommodates up to three (3) disposable pressure sensors. The calibrated pressure range is 0-60 psi. Any point within this range can be re-calibrated using an external pressure reference source. |
| Power: |
115/220-240 VAC, 60/50Hz, 75 Watts; double fused: T1AL 250V (CE: IR35A 250VAC) |
| Encoder: |
100 lines per motor revolution for 600 RPM motor. 120 lines per motor revolution for 8 and 160 RPM motors. |
| FilterTec™ Balance Options: |
1. Balance with capacity of 2,000 grams x 0.01 g resolution included with FilterTec™ CP-8. 2. Balance with capacity of 8100 grams x 0.1 g resolution included with all other FilterTec™ models. |
| FilterTec™ Software: |
Main menu with five operational modes including: 1. R/P Stat Mode: Constant Rate/Constant Pressure Filtration with six user-definable alarms. 2. P Stat Mode: Constant Pressure Filtration with six user-definable alarms. 3. R/P Step-Scan Mode: Automated continuous changing of pump rate or pressure with time. |
| Documentation Software for PC: |
1. SciDoc interface software with custom macros for Excel for data compilation. Sent to you ready to use. 2. Complete process analysis with graphing of data. 3. Real-time verification and documentation of process parameters. |
| Use Range: |
4 to 40 C, 100% Humidity |
| Motor: |
Choice between three (3) motors: 8, 160 and 600 RPM at 30VDC, 3.8 Amps, Variable Pump Speed, optically encoded servo-controlled motors. |
| I/O Ports: |
1. First serial port labeled Balance , Male DB9 connector for hook-up of electronic scale. 2. Second Serial Port labeled "Printer", Female DB9; also used to interface to PC for data storage in an Excel file in your PC. 3. External I/O port, Female DB37 connector; Used for remote On/Off control of FilterTec via footswitch. 4. Pressure Sensor Box: Phone plugs for three (3) pressure sensors. |
| Data Entry: |
Membrane keyboard with auditory feedback. |
© Copyright SciLog, Inc.
The FilterTec System increases dead end filtration (also called Normal Filtration) ultilization by over 35% using the FilterTec and its PMaintain Alarm. Use with your virus removing filters, sterilization filters, etc. Measures up to 3 pressures. Completely disposable fluid path is available: disposable tubing, disposable pressure sensors, disposable temperature sensors. SciDoc Documentation package for MS Excel is available for documenting the process.
FilterTec Plus™ Systems - Filterabilty Studies
| Dimension: |
Width: 5.75 in (14.6cm); Height: 8.5 in (212.6); Depth: 11in (27.9). |
| Weight: |
14 lbs (6.4kg) |
| Enclosure: |
16 Ga, aluminum baked epoxy blue |
| Pump Head/ Motor Options: |
1. Tandem 1081 peristaltic pump head with 8 RPM motor. Flow range (depending on tubing size): 0.03 to 24 ml/min. 2. Tandem 1081 peristaltic pump head with 160 RPM motor. Flow range (depending on tubing size): 0.5 to 554 ml/min. 3. Tandem 1082 peristaltic pump head with 600 RPM motor. Flow range (depending on tubing size): 0.59 to 2,258 ml/min. 4. Tandem 1081 peristaltic pump head with 600 RPM motor. Flow range (depending on tubing size): 2 to 1,500 ml/min. |
| Pressure Range: |
Tandem Head Pump: Maximum pressure output at tandem peristaltic pump head is 45 psi. Has single point recalibration feature. |
| Pressure Displayed: |
Pressure displayed with a resolution of 0.1 psi; choice of bar, psi, kpa |
| Pressure Sensors: |
Accommodates up to three (3) disposable pressure sensors. The calibrated pressure range is 0-60 psi. Any point within this range can be re-calibrated using an external pressure reference source. |
| Power: |
115/220-240 VAC, 60/50Hz, 75 Watts; double fused: T1AL 250V (CE: IR35A 250VAC) |
| Encoder: |
100 lines per motor revolution for 600 RPM motor. 120 lines per motor revolution for 8 and 160 RPM motors. |
| FilterTec™ Balance Options: |
1. Balance with capacity of 2,000 grams x 0.01 g resolution included with FilterTec™ CP-8. 2. Balance with capacity of 8100 grams x 0.1 g resolution included with all other FilterTec™ models. |
| FilterTec™ Software: |
Main menu with five operational modes including: 1. R/P Stat Mode: Constant Rate/Constant Pressure Filtration with six user-definable alarms. 2. P Stat Mode: Constant Pressure Filtration with six user-definable alarms. 3. R/P Step-Scan Mode: Automated continuous changing of pump rate or pressure with time. |
| Documentation Software for PC: |
1. SciDoc interface software with custom macros for Excel for data compilation. Sent to you ready to use. 2. Complete process analysis with graphing of data. 3. Real-time verification and documentation of process parameters. |
| Use Range: |
4 to 40 C, 100% Humidity |
| Motor: |
Choice between three (3) motors: 8, 160 and 600 RPM at 30VDC, 3.8 Amps, Variable Pump Speed, optically encoded servo-controlled motors. |
| I/O Ports: |
1. First serial port labeled Balance , Male DB9 connector for hook-up of electronic scale. 2. Second Serial Port labeled "Printer", Female DB9; also used to interface to PC for data storage in an Excel file in your PC. 3. External I/O port, Female DB37 connector; Used for remote On/Off control of FilterTec via footswitch. 4. Pressure Sensor Box: Phone plugs for three (3) pressure sensors. |
| Data Entry: |
Membrane keyboard with auditory feedback. |
© Copyright SciLog, Inc.
The FilterTec Plus System expands the capability of the FilterTec, creating a 3-filter testing station. Simultaneously test 3 like filters under constant rate conditions, or 3 different ones under constant pressure. Pressure and Collection Rate data collected from all three sensors and balances at the same time. SciDoc Documentation package for MS Excel is available for documenting the process.
LabTec™ Systems - Aseptic Small Volume Dispensing / Dilution
| Dimension: |
Width: 5.75 in (14.6cm); Height: 8.5 in (212.6); Depth: 11in (27.9). |
| Weight: |
14 lbs (6.4kg) |
| Enclosure: |
16 Ga, aluminum baked epoxy blue |
| LabTec Models: |
Optimal range for precision and speed of dispensing:
1. LabTec CP-120: 0.2 ml to 50 ml aliquots of low viscosity, aqueous liquids. Typical precision 0.5% by vol. Tandem 1081 peristaltic pump head with variable speed max. 160 RPM motor
2. LabTec CP-200: 10 ml to 2 liter aliquots of low or high viscosity liquids. Typical precision 0.5% by vol. Use with any thick, viscous liquids. Tandem 1082 peristaltic pump head with variable speed max. 600 RPM motor.
3.LabTec MP-320: 4 ml to 3 liter aliquots of organic solvents, low viscosity. Typical precision 0.5% by vol. liquids. Magnetic gear head, 316SS chamber with Teflon gears with variable speed max. 3400 RPM motor
|
| Pressure Range: |
Maximum pressure output at tandem peristaltic pump head is 45 psi. Has single point recalibration feature. |
| Pressure Displayed: |
Pressure displayed with a resolution of 0.1 psi; choice of bar, psi, kpa |
| Pressure Sensors Options: |
Use with sterilizing filters to monitor filter back pressure and to alarm when need to change filter due to plugging up of filter. |
| Power: |
115/220-240 VAC, 60/50Hz, 75 Watts; double fused: T1AL 250V (CE: IR35A 250VAC) |
| Re-Cal Feature: |
Factory installed calibration curve for all tubing sizes. Front panel Re-cal key for single-point pump recalibration. |
| LabTec™ Balance Options: |
1. Balance with capacity of 2,000 grams x 0.01 g and 8,100 g x 0.1 resolution are most popular. 2. Larger balance capacities up to 30 Kg x 0.1 g resolution available. |
| LabTec™ Software: |
1. Dispenses by volume, rapidly and with high precision 2. Dispenses by weight, used with balance for rapid high precision filling by weight 3. Weight ratio, automates weighing and diluting process and sample prep process 4. Monitors back pressure of in-line sterilizing filters 5. Alarms when back pressure of in-line sterilizing filter is plugged up and can no longer be used.
|
| Documentation Software for PC: |
1. SciDoc interface software with custom macros for Excel for data compilation. Sent to you ready to use. 2. Complete process analysis with graphing of data. 3. Real-time verification and documentation of process parameters. |
| Use Range: |
4 to 40 C, 100% Humidity |
| Motor: |
Choice between three (3) motors: 160, 600, 3600 RPM at 30VDC, 3.8 Amps, Variable Pump Speed, optically encoded servo-controlled motors. |
| I/O Ports: |
1. First serial port labeled Balance , Male DB9 connector for hook-up of electronic scale. 2. Second Serial Port labeled "Printer", Female DB9; also used to interface to PC for data storage in an Excel file in your PC. 3. External I/O port, Female DB37 connector; Used for remote On/Off control of FilterTec via footswitch. 4. Optional pressure sensor interface available |
| Data Entry: |
Membrane keyboard with auditory feedback. |
| LabTec Settings: |
- Save 10 Optimized Dispensing by Volume settings for rapid, high precision filling, from ml to liter aliquots; Typical precision of 0.5% by volume. - Save 10 Optimized Dispensing by Weight settings for rapid, high precision filling by weight from grams to kilograms aliquots; Typical precision of 0.3% by weight. - Save 10 Optimized Weight Ratio settings to automate the weighing and diluting process in sample preparation; Typical precision of 0.3% or better. - Document each dispense or dilution for GLP or for inventory control; print out or data sent to spreadsheet in PC. (SciDoc feature) |
© Copyright SciLog, Inc.
LabTec Aseptic small volume dispenser (0.25 ml to 4 liter aliquots); rapid, high precision filling, dispensing, diluting by weight or by volume. Alarms, documents each fill, completely disposable fluid path. Can be used with sterilizing filters to sterilize while dispensing. SciDoc Documentation package for MS Excel is available for documenting the process.
ChemTec™ Systems - Programmable Mass & Volume Flow Metering
The ChemTec family of programmable metering systems which can meter by weight or by volume. Programmable without a PC, have built-in alarms, interface with pressure sensor, scales, printers, valves, to give you safe, walk-away system operation. The SciDoc Documentation package for MS Excel is available for documenting the process with real-time data collection/graphing.. For the peristaltic models, a completely disposable fluid path is available.
Explore the ChemTec™
ChemTec™ Product Specs
View Larger Image
| Dimension: |
Width: 5.75 in (14.6cm); Height: 8.5 in (212.6); Depth: 11in (27.9). |
| Weight: |
14 lbs (6.4kg) |
| Enclosure: |
16 Ga, aluminum baked epoxy blue |
| ChemTec Pump Head / Motor Options: |
Peristaltic Models available with Tandem 1081 and/or 1082 heads:
1. Tandem 1081 uses Masterflex peristaltic pump tubing (thin-walled) sizes: #13, 14, 16, 25, 17 & 18.
2. Tandem 1082 uses Masterflex peristaltic pump tubing (thick-walled) sizes: #15, 24 & 35.
3. Tandem peristaltic heads can be piggyback to double flow range.
4. ChemTec CP-8, max. 8 RPM, Flow Range with one Tandem head: 0.03 - 24 ml/min.
5. ChemTec CP-120, max. 160 RPM, Flow Range with one Tandem head: 0.5 - 554 ml/min.
6. ChemTec CP-200, max. 600 RPM, Flow Range with one Tandem head: 2 - 2258 ml/min.
Piston Models available mounted with different sized piston heads & choice of wetted parts, e.g.
ceramic, 316SS, Kynar, Tefzel. Max pressure 25-100 psi depending on head choice:
ChemTec FM-420, max. 450 RPM, choice of RH piston head, Flow Range: 0.01 - 50 ml/min.
ChemTec FM-520, max 3400 RPM, choice of RH piston head, Flow Range: 2 - 370 ml/min.
ChemTec FM-200, max. 600 RPM, choice of Q piston head, Flow Range: 5 - 768 ml/min.
Magnetic Gear Models available mounted with different sized magnetic gear heads & choice of wetted
parts, e.g. Ryton, Teflon, 316SS. Pulse-less flow. Max. pressure 40-70 psi depending on head choice:
ChemTec MP-320, max. 3400 RPM, choice of magnetic gear sized head, Flow Range: 5 - 3,700 ml/min.
|
| Pressure Range: |
Maximum pressure output at tandem peristaltic pump head is 45 psi. Has single point recalibration feature, when used in volume metric mode. No calibration required when scale is hooked up. |
| Pressure Displayed: |
Pressure displayed with a resolution of 0.1 psi; choice of bar, psi, kpa |
| Pressure Sensors: |
Accommodates SciLog SciPres™ disposable pressure sensors. The calibrated pressure range is 0-60 psi. Any point within this range can be re-calibrated using an external pressure reference source |
| Power: |
115/220-240 VAC, 60/50Hz, 75 Watts; double fused: T1AL 250V (CE: IR35A 250VAC) |
| Encoder: |
100 pulses per motor revolution for 600 RPM motor.
120 pulses per motor revolution for 8 and 160 RPM motors, and 450 RPM and 3400 RPM motors |
| ChemTec™ Balance Options: |
1. Balance with capacity of 2,000 grams x 0.01 g and 8,100 g x 0.1 resolution are most popular. 2. Larger balance capacities up to 30 Kg x 0.1 g resolution available. |
| ChemTec™ Software: |
1. Main menu with eleven operational modes including 6 user definable alarms. 2. Meter by weight or by volume at a constant rate, with linear ramps or with exponential ramps.
|
| Documentation Software for PC: |
1. SciDoc interface software with custom macros for Excel for data compilation. Sent to you ready to use. 2. Complete process analysis with graphing of data. 3. Real-time verification and documentation of process parameters. |
| Use Range: |
4 to 40 C, 100% Humidity |
| Motor: |
Choice of five (5) motors: 8, 160, 600, 450 and 3400 RPM at 30VDC, 3.8 Amperes, Variable Pump Speed, optically encoded servo-controlled motors. |
| I/O Ports: |
1. First serial port labeled Balance , Male DB9 connector for hook-up of electronic scale. 2. Second Serial Port labeled "Printer", Female DB9; also used to interface to PC for data storage in an MS Excel file in your PC. 3. External I/O port, Female DB37 connector; Used for remote On/Off control of ChemTec™ via footswitch. 4. Pressure Box: Phone plugs for three (3) optional pressure sensors. |
| Data Entry: |
Membrane keyboard with auditory feedback. |
© Copyright SciLog, Inc.
|
View the ChemTec™ Product Brochure 361 KB
Quick Start Manual - Mass Flow Metering 331 KB
Quick Start Manual - Volume Flow Metering 362 KB
Automated Bioreactor Feed System 67 KB
Mass Flow Polymer Organic Synthesis System 67 KB
Easy-to-Use Preparative Chromatography System 98 KB
Diafiltration (TFF) System w/ SciPro™ 50 KB
|
| Dimension: |
5.75 Width x 6.25 Height x 11 Depth |
| Weight: |
11 lbs. |
| Enclosure: |
16 Ga, aluminum baked epoxy blue |
| ACCUTec Motor: |
Variable speed, 8 RPM, 160 RPM, 450 RPM, 600RPM and 3400 RPM motors at 28 VDC, 3.8 Amps; optically encoded, servo - controlled.
|
| Power: |
110 / 220 VAC , 60 / 50 Hz, 75 Watts; double fused |
| Encoder: |
120 lines per motor revolution. |
| Use Range: |
4 to 40 C, 100% Humidity |
| Motor: |
Choice of five (5) motors: 8, 160, 600, 450 and 3400 RPM at 30VDC, 3.8 Amperes, Variable Pump Speed, optically encoded servo-controlled motors. |
| I/O Ports: DB 15 (Back Panel) |
- RS-232 Serial port, DB15 connector, pin 2 (Transmit), pin 3 (Receive) & pin 5 (Ground)
- 4-20 mA input signal, DB 15 connector, pin 6 (Ground) & pin 13, with selection switch (back panel) at 4-20 mA
- 0-5VDC input signal, DB 15 connector, pin 6 (Ground) & pin 13, with selection switch (back panel) at 0-5VDC
- Pump Speed output signal, DB 15 connector, pulsed output between pins 7 (Ground) & pin 9, pulse rate is proportional to pump speed, ~5940 pulses/sec at 99% pump speed, ~3000 pulses/sec at 50% pump speed.
- Remote Start/Stop (Remote), closed contact closure (RUN), open contact closure (STOP) between pin 8 (Ground) & pin 15 of the DB 15 connector. This function is active when REMOTE has been selected from the front panel.
- Remote CW/CCW Motor Direction (Remote), closed contact closure (CCW), open contact closure (CW) between pin 7 (Ground) & pin 14. This function is active when the REMOTE mode has been selected from the front panel.
- Remote Start/Stop (Local), closed contact closure (RUN), open contact closure (STOP) between pin 8 (Ground) & pin 15 of the DB 15 connector. This function is active when the LOCAL mode has been selected from the front panel and the external contact closures (CC across pin 8 & 15) has been exercised, i.e. opening and closing the connected contact closures (CC). The front panel "RUN/STOP" key will be disabled at that point, however, the pump speed selection and the "CW/CCW" keys are still functional. The front panel "RUN/STOP" key function can be re-established by twice pressing the "LOCAL/REMOTE" key. NOTE: This operational mode should only be used when the ACCUTec pump is to be controlled (Stop/Start) by a SciLog Smart Pump, i.e. UltraTec or ChemTec.
- Foot Switch Start/Stop (Local), foot switch acts as an external contact closure, pump runs at the selected pump speed as long as the foot switch contact is closed, i.e. as long as you step on the foot switch. The pump stops when the foot switch contact is open.
|
| Data Entry: |
Membrane keyboard, 2 LED's with auditory feedback. |
© Copyright SciLog, Inc.
AccuTec™ Low Cost Tangential Flow Filtration Systems
The AccuTec TFF System is perfect for starting volumes of 50 ml to 5000 ml and has very low hold-up volumes. All wetted surfaces are low protein binding, chemically resistant materials. AccuTec TFF System Includes: Compact, High-Precision Accu peristaltic pump, Aseptic Reservoir Vessel, Magnetic Stirrer, Filter Holder, Two Pressure Gauges, and a Fittings/Tubing Start-up Kit.
| Dimension: |
5.75 Width x 6.25 Height x 11 Depth |
| Weight: |
11 lbs. |
| Enclosure: |
16 Ga, aluminum baked epoxy blue |
| ACCU Motor: |
Variable speed, 8 RPM, 160 RPM, 450 RPM, 600RPM and 3400 RPM motors at 28 VDC, 3.8 Amps; optically encoded, servo - controlled.
|
| Power: |
110 / 220 VAC , 60 / 50 Hz, 75 Watts; double fused |
| Encoder: |
120 lines per motor revolution. |
| Use Range: |
4 to 40 C, 100% Humidity |
| Motor: |
Choice of five (5) motors: 8, 160, 600, 450 and 3400 RPM at 30VDC, 3.8 Amperes, Variable Pump Speed, optically encoded servo-controlled motors. |
| I/O Ports: DB 15 (Back Panel) |
1. RS-232 Serial port, DB15 connector, pin 2 (Transmit), pin 3 (Receive) & pin 5 (Ground)
2. 4-20 mA input signal, DB 15 connector, pin 6 (Ground) & pin 13, with selection switch (back panel) at 4-20 mA
3. 0-5VDC input signal, DB 15 connector, pin 6 (Ground) & pin 13, with selection switch (back panel) at 0-5VDC
4. Pump Speed output signal, DB 15 connector, pulsed output between pins 7 (Ground) & pin 9, pulse rate is proportional to pump speed, ~5940 pulses/sec at 99% pump speed, ~3000 pulses/sec at 50% pump speed.
5. Remote Start/Stop ( Remote ), closed contact closure (RUN), open contact closure (STOP) between pin 8 (Ground) & pin 15 of the DB 15 connector. This function is active when REMOTE has been selected from the front panel.
6. Remote CW/CCW Motor Direction ( Remote ), closed contact closure (CCW), open contact closure (CW) between pin 7 (Ground) & pin 14. This function is active when the REMOTE mode has been selected from the front panel.
7. Remote Start/Stop ( Local ), closed contact closure (RUN), open contact closure (STOP) between pin 8 (Ground) & pin 15 of the DB 15 connector. This function is active when the LOCAL mode has been selected from the front panel and the external contact closures (CC across pin 8 & 15) has been exercised, i.e. opening and closing the connected contact closures (CC). The front panel RUN/STOP key will be disabled at that point, however, the pump speed selection and the CW/CCW keys are still functional. The front panel RUN/STOP key function can be re-established by twice pressing the LOCAL/REMOTE key. NOTE: This operational mode should only be used when the ACCU pump is to be controlled (Stop/Start) by a SciLog Smart Pump, i.e. UltraTec or ChemTec.
8. Foot Switch Start/Stop ( Local ), foot switch acts as an external contact closure, pump runs at the selected pump speed as long as the foot switch contact is closed, i.e. as long as you step on the foot switch. The pump stops when the foot switch contact is open.
|
| Data Entry: |
Membrane keyboard, 2 LED's with auditory feedback. |
© Copyright SciLog, Inc.
ACCU™ Digital Metering Pumps
Family of High Precision Digital Metering pumps, available with your choice of pump heads: peristaltic, piston & Magnetic gear models. Each ACCU includes the controller, choice of motor size and choice of pump head type. Ready to use.
| Dimension: |
Width: 5.75 in (14.6cm); Height: 8.5 in (212.6); Depth: 11in (27.9). |
| Weight: |
14 lbs (6.4kg) |
| Enclosure: |
16 Ga, aluminum baked epoxy blue |
| Pump Head: |
:RH1-CKC piston pump head. Material of construction: Kynar and Ceramic
|
| Power: |
115 / 230 V, 60 / 50 Hz, 75 Watts; double fused, Fuse Rating: TIAL 250V (CE: IR35A, 250VAC) |
| LabTec Methadone™ Software: |
1. Main menu with the following five (5) operational modes. 2. Serial Mode: Normal Methadone dispensing mode, implemented on power up 3. Volumetric Dispensing: For emergency use only 4. Weight Dispensing: Requires an OHAUS electronic balance. 5. Setup: Selection of user preferences and interface options. 6. Manual: Simple pump control; no alarms.
|
| Use Range: |
4 to 40 C, 100% Humidity |
| Motor: |
Variable speed, 3400 RPM (nominal) motor; RPM maximum at 24 VDC, 3.0 Amps; optically encoded, servo-controlled. |
| I/O Ports: |
1. First serial port labeled Balance , Male DB9 connector; connects to OHAUS Explorer balance. 2. Second serial port labeled Printer, Female DB9 connector; connects to user PC or Printer. 3. Phone jack connector labeled Foot Switch for remote RUN / STOP control of Vitex via foot switch. 4. DB37 labeled External I/O is not used in Methadone dispensing.
|
| Data Entry: |
Membrane keyboard with auditory feedback. |
© Copyright SciLog, Inc.
LabTec™ Methadone Dispensing Systems
In use in methadone treatment centers nationwide, the LabTec Methadone System provides automatic high precision computer controlled dispensing and documentation of methadone usage for government compliance and inventory control. Easy to use and calibrate, the LabTec Methdone System was specifically designed to meet the requirements of the methadone treatment industry.
| Dimension: |
Width: 5.75 in (14.6cm); Height: 8.5 in (212.6); Depth: 11in (27.9). |
| Weight: |
14 lbs (6.4kg) |
| Enclosure: |
16 Ga, aluminum baked epoxy blue |
| VitaPump Compatible Pump Heads & Tubing: |
Peristaltic pump head, SciLog TANDEM model 1081, with a 160RPM motor. Uses Masterflex tubing sizes: #13, 14, 16, 25 & 17. Magnetic Gear (Micropump) and Piston (FMI) models are also available.
|
| Power: |
Power: 110-120 / 220-240 VAC, 60 / 50 Hz, 75 Watts; double fused, Fuse Rating: TIAL 250V (CE: IR35A, 250VAC) |
| LabTec™ Software: |
1. Main menu with the following three (3) operational modes. 2. Metering Mode: Gravimetric vitamin metering, requires electronic balance. Several Labels available. (i.e. Vitamin A & D , Vitamin A , etc.) Two user-definable alarms. 3. Setup Mode: Selection of user preferences and interface options. 4. Manual Mode: Simple pump control (% Speed); no alarms.
|
| Use Range: |
4 to 40 C, 100% Humidity |
| Motor: |
160 RPM at 30VDC, 3.8 Amps, Variable Pump Speed, optically encoded servo-controlled motors. Motor encoded with 120 lines per motor revolution. |
| I/O Ports: |
1. First serial port labeled Balance , Male DB9 connector; connects to Ohaus, Mettler, and Sartorious Balances and Scales. 2. Second serial port labeled Printer, Female DB9 connector; connects to SciLog Printer or user PC. 3. Phone jack connector labeled Foot Switch for remote RUN / STOP control of VitaPump via foot switch. 4. DB15 labeled Valve V . Not used in vitamin metering applications. 5. DB37 labeled External I/O is used for alarm output (5.0 VDC, two-wire connection between pin 8 and pin 16). Remote RUN / STOP control input. Use a contact closure (i.e.solenoid switch) for remote control of VitaPump (two-wire connection between pin 19 and pin 37, ground |
| Data Entry: |
Membrane keyboard with auditory feedback. |
© Copyright SciLog, Inc.
VitaPump™ Vitamin Addition Systems
Easy-to-use and modestly priced, the VitaPump System provides automatic high precision metering by weight and documentation of vitamin usage for QC, Compliance and inventory for the Food and Dairy Industry. Avoid over fortification. Avoid under fortification. The VitaPump System was specifically designed to meet the vitamin fortification requirements set forth in the PMO Appendix O recommendations of the milk processing industry.
|